Overview
The Anritsu MS9780A measures optical spectra from 600 to 1750 nm for laser and LED analysis and optical component measurements. It accepts specified single-mode and graded-index multimode fibers. Anritsu identifies the MS9740B as its replacement.
Confirm the MS9780A configuration
Ask for the nameplate, optical port and adapter photos, and the installed wavelength-reference option. Include the wavelengths and conditions for any required trace or calibration document.
Ask about availability and request unit photos or test records · Buying FAQ
Model FAQ
Does ±0.05 nm accuracy apply throughout the wavelength band?
Anritsu specifies that figure near 1550 nm under stated fiber, resolution and reference-light calibration conditions.
What should I check before changing to an MS9740B?
Compare the optical connector, resolution, remote commands, and reference-light requirement for your setup.
Manufacturer documents
Specifications
Key Specifications
- Wavelength measurement range
- 600 to 1750 nm
- Minimum resolution setting
- 0.07 nm with specified single-mode fiber.
- Wavelength accuracy example
- ±0.05 nm at 1550 ±20 nm with 0.07 to 0.2 nm resolution and calibration using the wavelength-reference light-source option.
- Level range examples
- −90 to +10 dBm at 1250 to 1600 nm with attenuator off; −65 to +20 dBm at 1100 to 1650 nm with it on.
- Close-in dynamic range example
- 70 dB at ±1 nm from a 1550 nm peak in wide dynamic range mode at 0.07 nm resolution and 25 ±5 °C under stated conditions.
- Remote interfaces
- GPIB and RS-232C.
Sales and Service
- Warranty
- 6-Month Warranty
- Calibration Status
- Calibration certificate or test report available (as stated in your quotation)
- Manufacturer-Listed Standard Accessories
- Original manufacturer list: one optical connector adapter selected with the original order; one 2.5 m power cord; two F0012 3.15 A fuses (for 100 Vac system); two rolls of Z0312 printer paper; one operation manual (W1477AE); one remote-control manual (W1478AE); one RS-232C LabVIEW driver (MX978001S); one GPIB LabVIEW driver (MX978001G); and one B0239G front cover. The connector type and any factory light-source accessories depend on the ordered configuration. Manufacturer-listed standard accessories are a reference to the original model documentation. They do not guarantee the contents of a used instrument shipment. Confirm the actual supplied items for the specific unit before ordering.
Documents
Why work with us?
We check the details with you
From specifications to accessories, we help you understand what's included.
Know what you're buying
We share what we know about the condition, along with any available records.
Tell us what you need
Have a specific requirement or deadline? We'll focus on what matters to you.
No need to start over
We keep track of your questions and previous discussions, so it's easy to pick up where we left off.
A closer look at MS9780A